UNISSI designs and installs medical gas pipeline systems for wards, ICUs and operation theatres, from the plant room to the bedside outlet. We also maintain existing systems under CMC and supply cylinders, trolleys and consumables.
What we install
A complete MGPS, or any part of one when you are extending or upgrading.
How an MGPS works
Each gas runs in its own copper line from the plant room to the outlets, with valves to shut off one zone and alarms that warn staff before a patient is affected. Tap any part to see what it does, or tap a zone valve to shut it.
Swipe sideways to see the whole system.
All gases at normal pressure.
Selected part
Typical figures
What we check on a CMC visit
Outlet planner
Enter the beds and theatres on the new pipeline to see a first count of outlets for each gas. Your tender specification sets the final numbers.
Area valve boxes and alarm panels are planned per ward and theatre suite on the survey.
Gas identification
Every line carries a colour-coded ID band at regular intervals and at each turn. Each outlet is gas-specific, so an oxygen probe cannot fit a vacuum outlet.
| Gas | Symbol | Band colour | Typical supply |
|---|---|---|---|
| Oxygen | O₂ | White | 4 bar |
| Nitrous oxide | N₂O | Blue | 4 bar |
| Medical air | AIR | Black and white | 4 bar |
| Surgical air | AIR 7 | Black and white | 7 bar |
| Vacuum | VAC | Yellow | Suction |
| Carbon dioxide | CO₂ | Grey | Manifold, for laparoscopy |
From the plant room
Compressed air, oxygen control, alarms and the power behind them.
Recent MGPS work
Questions hospitals ask us
An MGPS carries oxygen, nitrous oxide, medical air, surgical air and vacuum from a central plant room to outlets at each bed and theatre, so staff do not move cylinders around the wards.
Seamless, degreased, de-oxidised medical-grade copper, typically to EN 13348 or ASTM B819 as the tender specifies, joined by flux-free silver brazing so no residue is left inside the pipe.
Periodic inspection and leak checks, testing of area and master alarms, servicing of source equipment such as compressors, vacuum pumps and manifolds, and repair or replacement of valves, outlets and consumables.
Yes. We tie the pipeline into PSA oxygen plants, liquid oxygen tanks and cylinder manifolds, with automatic changeover to backup supply.
Contact
Tell us the number of beds and theatres, the gases you need and the hospital's location. We will arrange a survey.
WW10, Windchants, Experion, Sector 112,
New Palam Vihar, Gurugram, Haryana 122017
Plot No 20, Village Raghopur,
Najafgarh, New Delhi 110071
Khasra No 53, Rajpura Patalwas,
Bassi, Jaipur, Rajasthan 303305