Medical gas pipeline system (MGPS) installation and maintenance
Every outlet, the right gas, the right pressure.
UNISSI designs and installs medical gas pipeline systems for wards, ICUs and operation theatres, from the plant room to the bedside outlet. We also maintain existing systems under CMC and supply cylinders, trolleys and consumables.
What we install
From the plant room to the bedside.
A complete MGPS, or any part of one when you are extending or upgrading.
Plant room
- Medical air plant, 4 bar
- Surgical air plant, 7 bar
- Medical vacuum plant with bacterial filters
- N₂O and CO₂ cylinder manifolds
- AGSS plant
- LMO tank and PSA plant tie-ins
Copper distribution
- Seamless degreased medical-grade copper
- Flux-free silver brazing
- Colour-coded gas ID bands
- Risers and branch lines
Isolation
- Area valve service units (AVSU) at every ward, ICU and OT
- Line valve assemblies on risers
- Non-return valves
Monitoring
- Master alarm panel for source equipment
- Area alarm panels at nurse stations
- Pressure transducers and switches
Terminal units
- Gas-specific outlets: BS, DIN or Ohmeda
- AGSS outlets in theatres
- Bed head panels
- Ceiling pendants
Patient equipment
- Oxygen flowmeters with humidifiers
- Vacuum regulators and suction jars
- Theatre vacuum units
- High-pressure hoses and probes
Outlet planner
How many gas outlets will you need?
Enter the beds and theatres on the new pipeline to see a first count of outlets for each gas. Your tender specification sets the final numbers.
- O₂
- —
- N₂O
- —
- Air 4 bar
- —
- Air 7 bar
- —
- Vacuum
- —
- AGSS
- —
Area valve boxes and alarm panels are planned per ward and theatre suite on the survey.
Gas identification
Colour codes we label every pipe with.
Every line carries a colour-coded ID band at regular intervals and at each turn. Each outlet is gas-specific, so an oxygen probe cannot fit a vacuum outlet.
| Gas | Symbol | Band colour | Typical supply |
|---|---|---|---|
| Oxygen | O₂ | White | 4 bar |
| Nitrous oxide | N₂O | Blue | 4 bar |
| Medical air | AIR | Black and white | 4 bar |
| Surgical air | AIR 7 | Black and white | 7 bar |
| Vacuum | VAC | Yellow | Suction |
| Carbon dioxide | CO₂ | Grey | Manifold, for laparoscopy |
Recent MGPS work
Pipelines we look after.
- ESIC Hospital, NoidaMGPS CMC
- Barpeta Cancer Centre, AssamMGPS CMC for Assam Cancer Care Foundation (2026)
- Police Hospital, Jammu40 oxygen and 10 N₂O D-type cylinders, 5 MGPS trolleys (2026)
Questions hospitals ask us
MGPS questions
What is a medical gas pipeline system (MGPS)?
An MGPS carries oxygen, nitrous oxide, medical air, surgical air and vacuum from a central plant room to outlets at each bed and theatre, so staff do not move cylinders around the wards.
What copper is used in a medical gas pipeline?
Seamless, degreased, de-oxidised medical-grade copper, typically to EN 13348 or ASTM B819 as the tender specifies, joined by flux-free silver brazing so no residue is left inside the pipe.
What does an MGPS CMC cover?
Periodic inspection and leak checks, testing of area and master alarms, servicing of source equipment such as compressors, vacuum pumps and manifolds, and repair or replacement of valves, outlets and consumables.
Can you connect the pipeline to a PSA plant or LMO tank?
Yes. We tie the pipeline into PSA oxygen plants, liquid oxygen tanks and cylinder manifolds, with automatic changeover to backup supply.
Contact
New pipeline, extension or CMC?
Tell us the number of beds and theatres, the gases you need and the hospital's location. We will arrange a survey.