UNISSI INDIA · EST. 1986

Home / Oxygen plants / Repair

PSA oxygen plant repair and restoration

Stopped plants, brought back to 93 %.

UNISSI repairs PSA oxygen plants that have stopped, trip, or no longer hold purity, whoever made them. We have restored PM CARES and DRDO plants and repaired L&T, Ozcan, Oxymat and Oxywise plants from 160 to 1,500 LPM, in hospitals from Kashmir to Assam and Rajasthan.

ABO₂

What we repair

Every stage of the plant.

A plant is only as good as its weakest stage. We look at all of them, starting with the air treatment that protects the zeolite.

AIR

Compressor

  • Trips, overheating and low delivery pressure
  • Controller faults and sensors
  • Service kits, oil and separator
TREATMENT

Dryer and filters

  • Refrigerated dryers not cooling
  • Blocked or failed auto-drains
  • Filter elements and housings
GENERATOR

Towers and valves

OUTPUT

Purity and delivery

  • Oxygen analyser calibration and replacement
  • Receiver, regulators and bacterial filters
  • Leaks on the line to the MGPS
SKID

Skid overhauls

  • Full skid repair on multi-skid plants
  • Pipework, fittings and gauges
  • Control panel wiring
POWER

Plant-room power

  • Servo stabilizers up to 150 kVA
  • Changeover to DG and to the cylinder manifold
  • Earthing and cabling

Plants we have repaired

Restorations and repairs.

  • GMC & AH Rajouri, J&KRestoration of 1,000 LPM PM CARES DRDO plant No. 3
  • District Hospital Ramban, J&KRepair of skid II, 1,500 LPM plant
  • District Hospital Kishtwar, J&KRepair of skid 1, 1,500 LPM plant
  • GMC Doda, J&KOne-time repair of PM CARES plant
  • District Hospital Budgam and SDH Tangmarg, J&KRepair of 300 LPM Oxymat and 500 LPM Oxywise plants (2026–27)
  • Kokernag, Anantnag, J&KRepair of a 400 LPM Ozcan plant
  • SKIMS MCH Bemina, J&KZeolite replacement, 750 LPM plant (2026)
  • NHM AssamOne-time repair of 30 oxygen plants at 27 hospitals, then CMC
  • GB Pant Hospital, AgartalaRepair of 1,000 LPM L&T plant
  • UPUMS, SaifaiOxygen plant repair
  • Sirohi and other Rajasthan hospitalsRepair of 160 LPM and 315 LPM plants

Questions hospitals ask us

Oxygen plant repair questions

Can you repair an oxygen plant that another company installed?

Yes. Most plants we repair were installed by other firms. We have worked on PM CARES and DRDO plants and on L&T, Ozcan, Oxymat and Oxywise makes, from 160 LPM to 1,500 LPM.

Why does a PSA oxygen plant lose purity?

The usual causes are moisture or oil reaching the zeolite because the dryer or filters are not working, a switching valve that sticks so the towers stop alternating, the hospital drawing more than the plant's rated flow, or a faulty oxygen analyser. We check each of these before replacing anything expensive.

Can you restore a plant that has not run for a long time?

Yes. We have restored plants that stood idle, including the 1,000 LPM PM CARES DRDO plant No. 3 at GMC Rajouri. We survey the plant, list what must be repaired or replaced, and hand it over only after it holds purity at rated flow.

Do you offer a maintenance contract after the repair?

Yes. Most of our repairs lead into a CMC, often with operators on site, so the plant does not stop again. This is how our NHM Assam and Jammu & Kashmir contracts run.

Contact

Plant stopped or below purity?

Send us the plant capacity, make, location and what you are seeing. We will tell you what it is likely to need and arrange an engineer.

Registered office · Gurugram

WW10, Windchants, Experion, Sector 112,
New Palam Vihar, Gurugram, Haryana 122017

Delhi

Plot No 20, Village Raghopur,
Najafgarh, New Delhi 110071

Jaipur

Khasra No 53, Rajpura Patalwas,
Bassi, Jaipur, Rajasthan 303305